Intumescent Electrical Products
Please click enlarge Images |
| MISDLFC - Solo Downlighter Covers Click for Specification |
|
|
This is a superb way of keeping up to an hours fire rating on
a ceiling.
Quick and easy to use this versatile product offers
full ventilation for the light
together with a complete
intumescent seal on the introduction of a fully
developed
fire. We think this is one of the best developments in the
downlighter market for a long time. If you don’t use them
already give our
sales team a call to discuss your
requirements further.
Feature include:
One range covers 30/60 min, low /high voltage
Ultra fast installation
Multiple wire access
|
Downlighter Size |
Description |
Hole Size |
Rating |
Packed |
Code |
150mm x 150mm |
FR Downlighter Cover |
50-75mm |
1hr |
1 or 12 |
MISDLFC150 |
200mm x 200mm |
FR Downlighter Cover |
75-100mm |
1hr |
1 or 12 |
MISDLFC200 |
250mm x 250mm |
FR Downlighter Cover |
100-150mm |
1hr |
1 or 12 |
MISDLFC250 |
300mm x 170mm*(30) |
FR Downlighter Cover |
150-270mm |
1hr |
1 or 12 |
MISDLFC300 |
350mm x 230mm*(30) |
FR Downlighter Cover |
150-270mm |
1hr |
1 or 12 |
MISDLFC250 |
| MISBEG - Electrical Box Pads |
|
Electrical Box Pads provide a permanent seal in fire
conditions. They are
suitable for fitting to conduit, plug and
switch boxes.
Features include:
Totally unaffected by water
Simple to use - easy to install |
Size (mm) |
Description |
Self / Adh |
Packed |
Code |
72 x 72 |
BESA Box Gasket |
Yes |
1+ |
MISBEG |
72 x 72 |
Adjustable Box Gasket |
Yes |
1+ |
MISABG |
72 x 72 |
Double Plug Box Gasket |
Yes |
1+ |
MISDPG |
72 x 72 |
Single Plug Box Gasket |
Yes |
1+ |
MISSPG |
72 x 72 |
|
Yes |
|
|
72 x 72 |
Single Shallow Box |
Yes |
1+ |
MISSSB |
72 x 72 |
Double Shallow Box |
Yes |
1+ |
MISDSB |
72 x 72 |
Marshall Tufflex Ceiling Rose Box |
Yes |
1+ |
MISMTC |
| MISFL - FL Expanding Foam |
|
There are two standard foams available on the market
today, one of which gives
a fire rating for the ‘surface
spread of flame’ only and one which offers a full
‘penetration seal’ for compartment walls. We are aware that
to the layman this
means little however to the occupant of
a building during a fully developed fire
the difference
becomes very apparent. As the use of these products tends
to be around the perimeter of door frames or sealing
services penetrating a
compartment wall. Which would
require full BS 476 part 20:22 penetration test
evidence,
which is the one on offer here.
Applications include:
Sealing around door and screen frames
Backfilling around non combustible service penetrations
Sealing irregular gaps |
| |
Description |
Size (ml) |
Rating |
Packed |
Code |
| |
FL Expanding Foam |
750 |
2hr* |
1+ |
MISFL |
| MISINT - Intumescent Mastic |
|
This adaptable intumescent mastic carries a 4 hour test report and is perfect for
sealing irregular gaps behind
frames etc. It comes in a standard 310ml cartridge
suitable
for use with a skeleton gun. The material is water based
and only
suitable in areas not in contact with water. This is
not suitable for use as a
glazing seal, please refer to our
glazing section for fire rated systems we
currently offer.
Applications include:
Sealing around door and screens
Backfilling around non combustible service penetrations
Sealing irregular gaps
BS 476 Part 20:22 4HR cavity protection |
| |
Description |
Colour |
Size (ml) |
Packed |
Code |
| |
Intumescent Mastic |
White |
310 |
1 or 25 |
MISINTW |
| |
Intumescent Mastic |
Brown |
310 |
1 or 25 |
MISINTB |
| MISPFB - Fire Rated Pillow |
|
There are a great idea for contractors who regularly cuts holes
in fire walls of a
buildings in use. Customers do expect a lot
sometimes, how are we to knock
holes in walls and every night
put the building back to its full fire status? This
pillow could be
your answer, it is re-useable and offers up to 4 hours fire
protection. Save the insurance claim, no builder should be
without, think of risk
verses outlay - then buy some.
Used within expansion joints primarily within
walls these
products combine an open cell fire rated foam material with
interlayers of intumescent. The result is a dry, quick to install
highly effective fire
barrier for use on linear gaps up to
100mm. Suitable for sealing expansion joints
in walls, in the
vertical plane.
Applications Include:
Concrete, masonry and porous concrete constructions
Concrete floor constructions
Underfloor brickwork, above ceiling compartments
Linear plane
BS 476 Part 20:22 4HR |
| |
Description |
Rating |
Size (mm) |
Packed |
Code |
| |
Fire Rated Pillow |
4hr |
300 x 200 x 25 |
1+ |
MISPFB200 |
| |
Fire Rated Pillow |
4hr |
300 x 175 x 45 |
1+ |
MISPFB175 |
| |
Fire Rated Pillow |
4hr |
300 x 60 x 20 |
1+ |
MISPFB60 |
| MISSHEET - 1.8mm Intumescent Sheet - Self Adhesive Back |
|
Intumescent sheets are a calendered product and is
supplied in rolls with a
standard width of 1 metre.
Possible Applications:
Inner lining of fire door panels.
Die cutting of pads for use under hinges,locks and door
closers.
Lining of safes, filing cabinets and storage boxes.
Features:
1.8mm Standard thickness
Intumescent sheets are totally unaffected by water.
Intumescent sheets are robust and difficult to tear.
Clean and safe to handle.
Easy to cut and shape
Health and Safety: According to 91/155/EEC Revision no.1 |
| |
Description |
Colour |
Size (mm) |
Packed |
Code |
| |
1.8mm Intumescent Sheet |
N\A |
200 x 200 |
1+ |
MISSHEET2 |
| |
1.8mm Intumescent Sheet |
N\A |
1000 x 1000 |
1+ |
MISSHEET3 |
|